Meter Data Quality Checks

Time Interval Consistency

  • Check for missing timestamps: Ensure that all hourly intervals are accounted for without missing entries.

  • Check for duplicate timestamps: Each timestamp should only appear once, representing a single observation for that hour.

  • Verify uniform intervals: Ensure that the data points are evenly spaced with a consistent interval of one hour.

Data Completeness

  • Identify missing values: Look for any missing or NaN (Not a Number) values in the dataset. Missing data should be flagged, interpolated, or imputed as appropriate.

  • Check for zero values: Validate whether zero values are legitimate or represent data errors.

Units and Format Consistency

  • Verify units of measurement: Ensure that all the data is in megawatt-hours (MWh) and convert any data that may be recorded in other units (e.g., kilowatt-hours).

  • Check for proper numeric format: Ensure that the values are numerical, and any unexpected data types (e.g., text, special characters) are identified and corrected.

Value Range Validation

  • Check for positive and negative values: Positive values should represent generation, and negative values should represent consumption. Check if these conditions are respected.

  • Detect extreme or unrealistic values: Flag any extreme or outlier values that may indicate erroneous readings (e.g., negative values for generation or excessively large values).

Data Consistency

  • Cross-check with Project Metadata: To ensure consistency, compare the data with project metadata, such as nameplate capacity.

  • Ensure temporal continuity: Validate that the power generation and consumption follow expected patterns (e.g., gradual increases or decreases, no abrupt spikes unless justified).

Handling Anomalies

  • Detect and correct anomalies: Identify and document potential data entry errors or device malfunctions (e.g., meter resetting) that may cause anomalies in the data.

  • Outlier detection: Implement statistical methods to identify and potentially remove or investigate outliers that could skew results.

circle-info

Out of range meter values are replaced with zero value.

Check for Consistent Data Availability Across Meters

  • Ensure synchronization between multiple meters: If data is collected from multiple power meters, ensure that each meter provides data for the same time intervals.

Validation of Negative Consumption Data

  • Consumption validation: For periods showing negative values (indicating consumption), cross-validate against other consumption data sources or historical trends to ensure correctness.

circle-info

For CFE generation, power consumption is excluded from the process. All negative values are replaced with zero values.

Data Timestamp Verification

  • Verify time zone accuracy: Ensure that the timestamps are aligned correctly with the expected time zone and that daylight saving time shifts are accounted for.

  • Handle potential time shifts: Identify any discrepancies due to meter resets or synchronization issues (i.e. daylight savings time).

Check Data Provenance

  • Verify data source and reliability: Ensure that the data is coming from a reliable source and that any transformations or pre-processing steps are documented and traceable.

Documenting these data quality checks in the methodology ensures transparency of the GC registry.